Height Adjustable Giraffe Warmer Servocuna Resuscitaire Infant Radiant Warmer

Model NO.: IRW-2001
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: LED
Information: Can Be Stored
Modes: Pre-Warm ,Manual or Automatic
Oxygen Cylinder: Yes
Vertical Height: Electric Adjusted
Tilt Angle of Bed: Stepless Adjustable
Heater Head: Adjusted
Silicon Mattress: Yes
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Model NO.: IRW-2001
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: LED
Information: Can Be Stored
Modes: Pre-Warm ,Manual or Automatic
Oxygen Cylinder: Yes
Vertical Height: Electric Adjusted
Tilt Angle of Bed: Stepless Adjustable
Heater Head: Adjusted
Silicon Mattress: Yes
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Height Adjustable Giraffe Warmer Servocuna Resuscitaire Infant Radiant Warmer 

Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
The information can be stored, consulted and indicated by the LCD display screen;
Failure alarm indication;
The angle of warmer module is adjustable horizontally;
Inclination of the bassinet is adjustable;
The panels around bassinet can be turned outward;
Silicon mattress is heatable and temperature is controllable;
With LED phototherapy function;
APGAR timer;
Vertical height adjustment (VHA) stand;
Disposable skin temperature sensor is optional.

Standard Configuration:
Main body (including the warmer module, controller, bassinet, main column and VHA stand), skin temperature sensor, I.V. Pole, mattress, tray and panels.

Specification:
Power requirement:  AC220V-230V/50Hz or AC110-120V/50-60Hz, 900VA
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Control accuracy:   ≤0.5ºC
Accuracy of skin temperature sensor:  ±0.2ºC
Temperature uniformity of mattress:   ≤2ºC
Mattress heating control range: 25-38ºC
Accuracy of mattress temperature display: ±0.7ºC
Angle of warmer module: ±60° , radiant heating focus on the mattress
Inclination of bassinet: The Max. angle on trendelenburg is 15°, on reverse trendelenburg is 20°
APGAR timer: audible and visible alarm when the device runs to 50″~1′, 4′50″~5′, 9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Max. bilirubin radiation on the mattress effective range: ≥1mW/cm2 
Average value general bilirubin radiation of on the mattress effective range: ≥0.8mW/cm2 
Bilirubin uniformity of radiating on the mattress effective range: >0.4
  Height Adjustable Giraffe Warmer Servocuna Resuscitaire Infant Radiant Warmer 

Brief Introduction:
Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;
The information can be stored, consulted and indicated by the LCD display screen;
Failure alarm indication;
The angle of warmer module is adjustable horizontally;
Inclination of the bassinet is adjustable;
The panels around bassinet can be turned outward;
Silicon mattress is heatable and temperature is controllable;
With LED phototherapy function;
APGAR timer;
Vertical height adjustment (VHA) stand;
Disposable skin temperature sensor is optional.

Standard Configuration:
Main body (including the warmer module, controller, bassinet, main column and VHA stand), skin temperature sensor, I.V. Pole, mattress, tray and panels.

Specification:
Power requirement:  AC220V-230V/50Hz or AC110-120V/50-60Hz, 900VA
Mode of control: Pre-warm mode, manual mode and baby mode are controlled by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Control accuracy:   ≤0.5ºC
Accuracy of skin temperature sensor:  ±0.2ºC
Temperature uniformity of mattress:   ≤2ºC
Mattress heating control range: 25-38ºC
Accuracy of mattress temperature display: ±0.7ºC
Angle of warmer module: ±60° , radiant heating focus on the mattress
Inclination of bassinet: The Max. angle on trendelenburg is 15°, on reverse trendelenburg is 20°
APGAR timer: audible and visible alarm when the device runs to 50″~1′, 4′50″~5′, 9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
Max. bilirubin radiation on the mattress effective range: ≥1mW/cm2 
Average value general bilirubin radiation of on the mattress effective range: ≥0.8mW/cm2 
Bilirubin uniformity of radiating on the mattress effective range: >0.4
 

Organic Goji Berries

Organice Goji Berries are Certified by USDA, BCS.

Low Pesticides Goji Berries

Low Pesticides Goji Berries are Tested by Eurofins

Conventional Goji Berries

Conventional Goji Berries are Certified by Chinese Food Testing Institutions

Goji Berries

Goji Berries,Dried Goji Berries,Goji Berry Fruit,Goji Fruit

Ningxia GuoGuoLaoDie Food Co., Ltd. , http://www.lovegojiberries.com