Infant Baby Radiant Warmer Bn-100A (standard)

Model NO.: SC-ZZDSBN
Model NO.: SC-ZZDSBN
Infant Baby Radiant Warmer

Brief introduction:

1. Microprocessor based servo controlled temperature system.

2. Alarm functions for safety includes: Power failure, temperature deviation, Temperature sensor failure, over temperature.

3. Transparent protector folded

4. Alarms are audible and visual

5. A second thermal cut-out function for more safety

6. Skin temperature sensor failure protect function avoid over temperature

 

Standard configuration

Main body (including the radiant source, control system, infant bed, bracket), X-ray cassette, I. V. Pole, skin temperature sensor, tray, mattress, transparent protector, castors.

Optional parts: Drawer, RS-232(485) connecter

 

Technical data:

1. Power supply: 110/220V 60/50Hz

2. Power input: ≤ 1200VA

3. Operating condition

An ambient Temperature: 18°C-30°C

An ambient Relative Humidity: 30--75 percent RH

Atmospheric Pressure: 700~1060 hPa

An ambient Air Velocity <0.3m/s

4. Temperature control: 32~38°C

5. Temperature control accuracy: ≤ 0.5°C

6. Mattress temperature uniformity: <25°C

7. Skin temperature sensor accuracy: + /-0.3°C

8. Warm-up time: ≤ 30min

9. Infant bed tilt angle: + 10degree

10. APGAR timer range: ≤ 24h

11. Heater head horizontal: 90degree;

12. Mattress size: 67cm X 54cm

13. Distance from heater to mattress: 80cm

 

Transport and storage

Environment Temperature: -40~ +55°C

Environment Relative Humidity: ≤ 95percert Atmospheric Pressure: 500~1060hPa

 

Package:

Each unit is packed one case

Size: 110cmX 78cm X 86cm

Gross weight: ≤ 90kg

Infant Baby Radiant Warmer

Brief introduction:

1. Microprocessor based servo controlled temperature system.

2. Alarm functions for safety includes: Power failure, temperature deviation, Temperature sensor failure, over temperature.

3. Transparent protector folded

4. Alarms are audible and visual

5. A second thermal cut-out function for more safety

6. Skin temperature sensor failure protect function avoid over temperature

 

Standard configuration

Main body (including the radiant source, control system, infant bed, bracket), X-ray cassette, I. V. Pole, skin temperature sensor, tray, mattress, transparent protector, castors.

Optional parts: Drawer, RS-232(485) connecter

 

Technical data:

1. Power supply: 110/220V 60/50Hz

2. Power input: ≤ 1200VA

3. Operating condition

An ambient Temperature: 18°C-30°C

An ambient Relative Humidity: 30--75 percent RH

Atmospheric Pressure: 700~1060 hPa

An ambient Air Velocity <0.3m/s

4. Temperature control: 32~38°C

5. Temperature control accuracy: ≤ 0.5°C

6. Mattress temperature uniformity: <25°C

7. Skin temperature sensor accuracy: + /-0.3°C

8. Warm-up time: ≤ 30min

9. Infant bed tilt angle: + 10degree

10. APGAR timer range: ≤ 24h

11. Heater head horizontal: 90degree;

12. Mattress size: 67cm X 54cm

13. Distance from heater to mattress: 80cm

 

Transport and storage

Environment Temperature: -40~ +55°C

Environment Relative Humidity: ≤ 95percert Atmospheric Pressure: 500~1060hPa

 

Package:

Each unit is packed one case

Size: 110cmX 78cm X 86cm

Gross weight: ≤ 90kg