Intelligent biochemical incubator

Intelligent biochemical incubator

Clicks: 3135 Release time: 2016/5/24

The intelligent biochemical incubator biochemical incubator has two-way temperature regulation system for cooling and heating, and the temperature controllable function. It is a laboratory, indispensable laboratory equipment for plant, biology, microbiology, genetics, virus, medicine, environmental protection, etc., widely used. At low temperature constant temperature test, culture test, environmental test, etc.

Its main features:

1. The insulation material of the box body is made of polyurethane foam foamed in the field, which has strong anti-interference ability to the external heat (cold) source.

2. The inner cavity is made by engineering plastic molding process and has strong corrosion resistance.

3. The all-glass door is convenient for observing the working cavity.

4. In order to protect the refrigeration compressor, the control circuit is designed with power-off protection and 4-minute delay function.

5, the temperature is automatically controlled, the red LFD display shows the number is intuitive and clear.

Instructions for use:

1. Place the incubator on a flat and solid ground and adjust the two supporting screws at the lower end of the box to make the box stable.

2. Plug in the power socket (the power supply should be well grounded), press the “power switch”, the display will be on, and the display shows the actual temperature and working time in the incubator room.

3. Time setting: The time setting includes the setting of "minute" and "hour". Press the “SET” setting button. When the decimal point of the “minute” digital tube display position is lit, enter the “minute” setting state, and then press the “▲” or “▼” button to confirm the “workbox” work. Minute "time (zui is 59 minutes long); press the "SET" button again. When the decimal point in the lower right corner of the "hour" digital tube display position is lit, the "hour" setting state is entered, and then press "▲" or "▼". "Key to confirm the "hour" time of the incubator for this job (zui is 99 hours long).

4. Temperature setting: press the “SET” button. When the decimal point in the lower right corner of a digital tube is illuminated after the temperature is displayed, enter the temperature setting state, and then press the “▲” or “▼” button to confirm the incubator. Set the temperature this time (the set temperature range is 5 °C ~ 50 °C). When the above steps 3 and 4 are completed, press the “ENTER” confirmation button to confirm the current working time of the incubator and the operating temperature (set temperature) in the incubator. Note: After the temperature setting is confirmed, the temperature cannot be set back and forth frequently, so as to avoid frequent compressor starting, causing overload of the compressor and affecting the service life of the compressor.

5. If you need to check the working time and temperature set by the incubator this time, press the “SET” button, the display panel will display the set time and temperature, and then press the “ENTER” button, the display value of the incubator will be restored. Go to the original working state.

6. If the lighting needs to be illuminated in the incubator, press the “lighting switch”; if there is no need for lighting in the box, the lighting switch on the panel should be placed in the “off” position to avoid affecting the upper temperature.