The small tablet press presses various granular raw materials into round pieces, which is suitable for laboratory trial production or small batch production of various tablets, sugar tablets, calcium tablets and the like. It is a small bench-top electric (manual) continuous tableting machine. The machine is equipped with a die, the filling depth of the material and the thickness of the tablet can be adjusted.
Technical Parameters:
Die number: 1 pay
Zui large tablet pressure: 15Kn
Zui large tablet diameter: φ12mm
Zui large tablet thickness: φ6mm
Production capacity: 3500-4000 pieces / h
Electric machine: 550w, 1400 rpm, 220V
Dimensions: 580 × 450 × 625mm
Host weight: 85kg
Small tablet press instructions:
First, use and characteristics
Serial number | Refueling part | Lubricating oil | Number of refueling per shift |
1 | Spindle hole oil cup (2 pieces) | butter | 2-3 times |
2 | Eccentric wheel shell oil cup 1 | butter | 2-3 times |
3 | 1 bridge axle oil cup | butter | 2-3 times |
4 | Lifting the cam groove (ie the groove inside the large gear) | butter | Every week, check the surface of the groove to wipe off the dirt and add butter once. |
5 | Filling the groove of the cam | butter | Every shift inspection, depending on the situation |
6 | Gear tooth surface | butter | Every shift inspection, depending on the situation |
7 | Oil hole on connecting rod | Motor oil | 1 time |
8 | Swing pivot point of the lever | Motor oil | 1 time |
9 | Upper punching rod surface | Motor oil | 2 times |
10 | Lifting rod surface | Motor oil | 2 times |
Seven, common faults
Serial number | category | Fault conditions | The cause of the failure | Failure prevention and treatment |
1 | Top car | After rushing into the middle mold, "top dead", the machine stops running | (1) The pressure is too large; the tablets are too hard (2) repeated feeding (3) The eccentric wheel shell and the spindle hole lack oil, the rotation resistance is too large, and even the phenomenon of “bite death†occurs due to severe wear. (4) The belt is too loose (5) Improper starting position (6) The hand is not strong enough | (1) Adjust the pressure gradually. Do not adjust too much at one time, and the tablets can't be pressed too hard. (2) Avoid repeated feeding. See No. 7 (3). Always keep lubricating. If it has been seriously worn or “killedâ€, it must be disassembled and repaired immediately. (4) Adjust the belt, see the precautions for use, Article 3, (5) See the precautions for use, Article 6. (6) When the hand presser is pressed or the upper punch passes the low point of Zui, it must be more forceful. (7) For the treatment method after the top car, see Article 7 of the precautions for use. |
2 | Not working well | Generally not working properly | The friction surface of the moving parts lacks oil, enters dirt, rusts, and seriously wears out the parts. | Always check each part to keep it clean and lubricated (see lubrication maintenance section 1). If there is any bad condition, repair it immediately, and do not deteriorate or damage the machine. |
Heavy or blocked when the undershoot rises | (1) Since the surface of the die is not light or worn; or due to improper granulation of the ingredients, the powder adheres to the surface of the punch and the middle mold, which increases the resistance of the sheet. (2) The lifting cam is seriously worn or enters the sundries (3) improperly adjusted, so that the lower punching rod rises and the middle mold is ground. | (1) If the die is found to have a sticking phenomenon, replace the die or reprocess the drug according to the situation. (2) Check and repair, keep it clean and lubricated. (3) Pay attention to adjustments | ||
3 | vibration | Abnormal vibration | (1) Loose parts and screws (2) The parts are seriously worn (3) The friction surface is dry or lacks oil or enters the dirt | (1) Regular inspection, see section 2 of lubrication maintenance, (2) frequent inspections, timely repair of worn parts. (3) Always pay attention to the cleaning and lubrication of each friction surface, especially pay attention to the direct view, but the working load is the important friction surface of the main shaft and the eccentric. |
4 | Wear | The friction surface of the main shaft and the hole is quickly worn or even burned out. | Lack of oil, enter impurities | Always keep clean and lubricated, the lubricant used must be clean and free of impurities |
Rapid wear and tear on the bridge axle and sleeve | Ibid. | Ibid. | ||
Upper punching rod and sleeve wear and wear quickly | Ibid. | Ibid. | ||
Lifting cam groove wears quickly | In addition to the above reasons, there are: (1) improper granulation of the ingredients, or the surface of the die is not light, the sticking phenomenon occurs, the sheet resistance is increased and the load of the cam groove is increased, and the wear is rapidly worn. (2) The lifting roller is turned too tight or rusted. Do not move. | (1) Check the die. If there is a sticking phenomenon, replace the die or re-dosing and granulating according to the situation. (2) Remove and repair | ||
Die surface wears quickly | (1) Improper adjustment, the upper punch and the friction in the mold phase, (2) improper granulation of the ingredients, such as too little slippery material, too thick powder. | (1) Adjusted separately (2) Reprocessing the drug | ||
5 | Feeder damage | Battered with the undershoot | (1) The film is not properly adjusted, the lower punch is higher than the middle die plane, (2) the lower punching fixing screw is loose, and the lower punching rises out of the middle die plane. | When installing and adjusting the die, be sure to find that the screw is loose. Immediately tighten the die to the bottom of the die. |
Battered under the middle mold | The middle mold fixing screw is loose, and the middle mold rises out of the plane of the middle mold platen. | Ibid. | ||
Being hit by | (1) Reverse during adjustment, causing collision (2) When the adjustment, the position of the upper punching rod is too low, and turning the handwheel causes a collision | Pay attention when adjusting | ||
6 | Difficult to unload | The upper punch, the lower punch or the middle die cannot be taken out in the hole | (1) The size of the die or the die hole size of the tablet press is unqualified, and the fit is too tight. (2) rusting with the countertop | (1) Pay attention to the installation if you find that the fit is too tight (2) Wipe the mating surface and apply a layer of oil film during installation. Do not remove the die to clean the mating surface for a long time, apply anti-rust oil, and keep it properly. |
7 | Overlapping piece | Two feedings into one piece | When the tablet is adjusted, the handwheel has not been ejected and the handwheel is reversed to cause the feeder to repeatedly feed, resulting in overlapping sheets. | Be careful not to reverse when adjusting. If you have repeatedly added the material but have not yet become a superimposed piece, you can slowly reverse the handwheel to lift the top of the tablet to remove the added material and pull out the tablets. If it has been pressed into an overlapping piece and the car is topped, it will be handled according to the top car (see Note 7 for use) |
8 | Jumping and fragmentation | When the pill is shot, it is too bouncing or broken | (1) The film is not properly adjusted, and the lower punch surface is lower than the middle mold plane. When the tablets come out, they are blocked and even crushed. (2) The middle mold fixing screw is loose, and the middle mold rises to block the film. | (1) See page 2, page 2 (2) Adjusting the tightening medium mold |
9 | Unedged piece and cracked piece | The tablet is scratched from the middle surface of the middle mold, and even the tablet is broken. | (1) The middle mold finish is unqualified or worn and scratches the circumferential surface of the tablet. At the same time, the tablet is cracked due to the unsmoothness of the film. (2) Miscibility of the granulation of the ingredients occurs, resulting in a burr or a crack. | (1) Replace the middle mold (Note: the middle mold can be turned over after one side wears, and the other side is used) (2) Reprocessing the drug |
10 | Not only pills | There are pits or uncovering on the surface of the tablet. | (1) The surface of the punch is not only (2) improper granulation of ingredients | (1) Repair punch (2) Reprocessing the drug |
11 | Loose tablets | Pills are not enough, loose and brittle, layered, etc. | (1) insufficient pressure (2) improper granulation of ingredients | (1) Adjust the pressure (see Article 4 on page 4) (2) Reprocessing the drug |
12 | The film is unstable | The difference in weight is too large | (1) The undercut fastening screw is loose, and the lower punch is raised to feed the filling amount. (2) The butterfly screw is loose, the lower adjustment wheel rotates, the filling amount is changed, (3) the particle is tight and the size is uneven. | (1) Press the lower punch to the end and tighten the lower punch fixing screw (2) Re-adjust and tighten (3) Pay attention to the granulation of the ingredients, especially when crushing the pieces and crushing them. |
If you want to know more about the tablet press , please log in to our company :< > Or direct pharmaceutical technology department : <> consulting, our factory will provide you with more professional services!
This product is made of barrel , plunger ,piston and needle.This barrel should be clean and transparent enough to easy observe.Barrel and piston matches well and it has a good property of sliding,and is easy to be used.
The product is applicable to push the solution to the blood vein or subcutaneous , also can extraction blood from the human body in the veins.It suits users of different age and is the basic methods of infusion.
5ml Disposable Medical Sterile Syringe
5ml ;Disposable Medical Sterile Syringe;Medical Factory
Changzhou Yuandong Medical Equipments Co.,Ltd , https://www.czydmedical.com