Causes and troubleshooting of common faults in pelleting machines

Causes and troubleshooting methods for common faults in pelleting machines:

Common faults of this machine:

1. After the machine is powered on, the motor does not run.

cause:

1. Poor contact of the power cord or loose power plug;

2. Poor contact in the switch.

Remedy (you must turn off the power to do the following):

1. Repair the power supply or exchange the plug of the same specification;

2. Repair or replace the same size switch.

Common faults of this machine:

When the mechanism is pill, the shaft knife rotates or the medicine surface sticks.

cause:

The output stop lever is loose and there is a distance from the bottom of the shaft cutter. The pill cannot be scraped off the shaft slot.

Remedy (you must turn off the power to do the following):

Adjust to the distance between the discharge plate and the bottom of the shaft sipe, (about 0.1mm) and tighten the set screws.

Common faults of this machine:

When the unit is working, the motor stops suddenly.

cause:

1. Capacitance is broken.

2. The gear is stuck.

Remedy (you must turn off the power to do the following):

Check the gear slots for debris and clean them.

Common faults of this machine:

When the machine is working, the shaft cutter has a slight jump.

cause:

Block compression screw loosening <br> <br> troubleshooting (must be cut off, in order to perform the following operations):

Open the top cover and tighten the 6 hexagon socket screws evenly.

Common faults of this machine:

The machine during operation, abnormal noise <br> <br> Reason:

1. The shaft knife and the friction part of the body are dry and oil-free;

2. There is no oil between the gears.

Remedy (you must turn off the power to do the following):

1. Inject a few drops of clean cooking oil into the oil eye;

2. Apply a small amount of butter to each gear groove.

Common faults of this machine:

The heater has failed to heat up.

cause:

1. The plug is loose or the power cord is off;

Remedy (you must turn off the power to do the following):

Replace the plug of the same specification or repair the power socket;