Clever removal of the iron filter element of the iron filter air filter is difficult to clean with diesel oil. If the filter element is stained with diesel, it can ignite and burn. After the fire is extinguished, the filter element is knocked with a wooden stick so that the soot falls off and the dirt inside and outside the filter element can be completely removed.
When the elasticity of the piston ring is suspicily suspected of insufficient elasticity of the piston ring, a standard new ring of the same type and the old ring being examined can be placed along the circumference and placed vertically so that the openings of both rings are in a horizontal position. Then press the two rings by hand. If the opening of the new ring does not move, the opening of the old ring has been closed, indicating that the old ring is flexible and can continue to be used.
The engine oil of the S195 diesel engine in the engine of the exhaust pump is a rotor type oil pump. If the air in the pump is not drained, there will be a failure to pump oil. The trick is to use a medical waste needle to fill up the oil, fill it into the pump inlet, and turn the oil pump to make the outlet out of the oil.
Skillfully repair the connection between the nose of the high-pressure tubing of the high-pressure tubing and the injector and the oil valve. The sealing accuracy is ensured by the machining accuracy of the contact surface and the fastening force of the tube nut. Once the contact surface is worn out, a circular copper degree can be cut from the waste cylinder pad, and a small hole can be made in the middle, between the bump and the pit.
Cleverly fill the breakage pad and place it on the breakage. Apply a little butter on both sides of the paper pad, and then cut two thin white papers with the size of the paper pad, stick them on both sides of the paper pad, and put them on the machine. Tighten the nuts to eliminate leakage.
It is not easy to remove dirt and dirt from the dirty rotor oil filter in the fine filter. If a layer of paper is applied to the inner wall of the rotor with butter, and the soil is attached to the paper, the paper can be removed and the soil can be completely removed.
In addition to the scale, two large peeled, seeded old loofahs are cleaned and placed in a water tank, which can be replaced regularly.
Cleverly rule the tires to take 2 tablespoons of talcum powder, remove the valve core, and let the air out. Use a hard paper to make the funnel and insert the valve. Load talcum powder into the inner tube. When the irrigation is not in progress, the paper funnel can be removed. After the wheels are turned, they are filled until they are finished. Then fill the valve core with sufficient gas. After inflated, talcum powder is dispersed in the fetus and diffusely attached to the inner wall of the femur, which can stop tiny air holes from spreading.

Increasing complexity of operation theater/ICU equipment requires Medical Pendant more expansibility, reliable, convenience. Lewin series medical pendant combined LEWIN abundant operation room/ICU equipment produce and integrate experience, the design follows human body enginerring principle; The ceiling pendnat function fits doctor and patient's actual using demands, pay attention to convenient actual operation, can meet different environment demands, has highly cost-effective;