Features
Interlayer design, the vacuum system adopted injection water pumping, higher working stability, longer non-maintenance cycle
pulsating vacuum -0.92 bar
limiting vacuum -0.96 bar the best effect of sterilization
safety door interlock, over temperature protection automatically
water quality monitoring system, avoiding secondary contamination of the instruments because of the water problem
sterilization standard: CLASS B
Â
It is suitable for the use in hospital and scientific research unit. The autoclave can meet the sterilization requirements of operation appliances, dental instruments, medical dressings, glassware, injection wares which can endure the high temperature pressure.
Â
Data Parameters:
Â
Program name | Sterilzation temperature |
Sterilzation time | Drying time | Pulse time |
Universal program | 134ºC | 6min | 10min | 3 |
Quick program | 134ºC | 4min | 5min | 3 |
Gentle program | 121ºC | 20min | 10min | 3 |
Custom program | 115-134ºC | 4-30min | 0-30min | 16 |
Bowie&Dick test | 134ºC | 3.5min | 5min | 3 |
Bowie&Dick test | 134ºC | 3.5min | 2min | 3 |
Vacuum test | Â | Â | 15min | Â |
Drying program | Â | Â | 15min | Â |
Â
Operates easily
Chinese and English language operation
The selected matches the printer, but real-time record antiseptic process
Sterilization chamber with reasonable use of space
0.22mincron living thing filter
Â
Â
Â
 Standard Dental AutoclaveSterilizer
Machine dimensions                            | 780*420*512*mm |
Sterilization chamber size                     | Φ200*650mm |
Sterilization chamber volume                      | 21L |
Net weight                                        | 55kg |
Electrical rating                            | AC220V±10%                                        50Hz±1Hz  13A Max  2.7kVA |
Steam temperature                            | 110-135ºC |
YJ-22Â Standard Dental AutoclaveSterilizer
Â
Machine dimensions                            | 780*420*512*mm |
Sterilization chamber size                     | Φ250*650mm |
Sterilization chamber volume                      | 22L |
Net weight                                        | 55kg |
Electrical rating                            | AC220V±10%                                        50Hz±1Hz  13A Max  2.7kVA |
Steam temperature                            | 110-135ºC |
Â
Indication:
Acute metabolic disorder: such as debility of female animal after giving birth and disease.
Chronic metabolic disorder: early disease of young animal, malnutrition, growth blocked;
Metabolic disorder:: inappetence, Lactation reduction, stress, Frailty.
Catalepsy caused by anemia, exhaustion.
Improve animal immunity and growth of young animals.
Enhance muscular and body strength of racing, working or laying animals.
Vitamin B12 Injectionis for animals malnutrition, improper raising management and disease-caused metabolic disturbance, dysplasia of young animals, reduction of immunity and depression.It bears strong antioxidation, in low concentration, effectively restraining the autoxidation of fat and increasing the anabolism of each part of animal body by simple physical stimulating mode, improving function of liver,, smooth muscle and skeletal system, helping the muscular system recovering from tiredness, lower the stress reaction.
Vitamin B12,Vitamin Supplement,Vitamins For Energy,Vitamin B12 Injection
Hebei Kexing Pharmaceutical Co., Ltd. , http://www.kexingpharma.com